LogicLadder changes a parameter's range, unit, multiplication factor or alert limit in TSC Enviro™ for you. Send all the details in one request and it is usually done the same day.
What to send to support
| Change | Include |
| Range (4-20 mA) | Station, parameter, old range and new range. Confirm the new range is also set on the analyser. See Checking 4-20 mA Readings and Ranges. |
| Multiplication factor | Station, parameter and the factor, for example 0.1. |
| Unit | Station, parameter, current unit and new unit, for example ppm to mg/Nm³. The unit in your CTO is useful. |
| Alert limit | Station, parameter, limit value, and the emails and mobile numbers to notify. |
What you change yourself
Changing a unit, range or factor in TSC Enviro™ does not change what the regulator has on record. If the regulator portal has the wrong unit or parameter, your industry changes it there. It must match your CTO.
| Portal | How your industry changes a unit or parameter |
| CPCB ODAMS (new OCEMS portal) | Log in, click Edit on the device. This sends an edit access request to CPCB. When CPCB approves it by email, make the change and submit again. Then tell LogicLadder, so the mapping matches. |
| Old CPCB portal (RTDMS) | Email CPCB (the concerned IPC division) with the change, normally with an updated OCEMS connectivity sheet. CPCB makes the change on its side. |
| SPCB portals | Follow that board's process, or ask support: on most SPCB portals LogicLadder sends the data and can update the mapping with you. |
What happens next
- Support makes the change and replies with a screenshot of the new setting.
- If the values still look wrong after the change, support checks the raw values from the analyser. See Readings Don't Match the Analyser.
Related articles
- Readings Don't Match the Analyser – units, ranges and analyser faults behind values that differ.
- Checking 4-20 mA Readings and Ranges – how a 4-20 mA signal becomes a reading, and how to check it.
- Creating an Instantaneous Alert Rule – alert when a reading crosses a limit.
- Adding a Parameter to a Field Instrument – units, register mapping, multiplier and offset.