Use this article if you receive a notice or show-cause letter from CPCB or an SPCB about low data availability, data gaps or exceedances. Your industry replies to the board. LogicLadder helps you find the cause and gives you the evidence.
Check these first
- Note the stations and the exact dates in the notice.
- Run the Data availability report for those stations and dates. See Data Availability Report.
- For an exceedance notice, run the Limit exceedance report and check your alert limits match your consent to operate (CTO). See Limit Exceedance Report.
- Work out where the gap came from:
- Gap in TSC Enviro™ too: the station was offline, for example a power cut, UPS failure or SIM problem at site. See Station Offline or Data Not Updating, Data Gaps After a Network or Power Outage.
- Data in TSC Enviro™ but not on the portal: the problem was between TSC Enviro™ and the regulator. Check Compliance > Summary > View logs for that period. For ODAMS, See Data Not Showing on CPCB ODAMS. For the old CPCB portal or an SPCB, See Data Not Showing on the Old CPCB Portal (RTDMS) or an SPCB Portal.
- Check whether a maintenance or shutdown was recorded for that period. See Reporting a Shutdown or Maintenance Period.
- Check the alarms raised for those instruments during the period. See Viewing Configured and Generated Alarms.
Alerts on ODAMS
On ODAMS, the new OCEMS portal, CPCB also raises automatic alerts under its 2025 alert protocol, for exceedances, connectivity failures and readings that stay abnormally constant. Alerts come in three levels: Yellow (Level I), Orange (Level II) and Red (Level III). Orange alerts must also be reported to the SPCB or CPCB, and Red alerts need you to stop the discharge or emission and take urgent action. Act on alerts as they come: unanswered alerts build a record that can lead to a notice.
On the old CPCB portal (RTDMS), notices usually come from the board as letters or emails, based on the data it received.
What to send to support
- The notice or ODAMS alert (PDF or screenshot) and the period it covers.
- Which portal it came from: ODAMS, the old CPCB portal or an SPCB.
- Industry and station names.
- Your data availability or exceedance report, if you ran one.
- A screenshot or short video of anything that looks wrong in TSC Enviro™.
If the checks above don't solve it,
raise a ticket with support. Mention the board's deadline, so support can prioritise.
What happens next
- Support checks the record for the period and tells you the cause, for example "gateway offline from 6 to 19 May" or "regulator server timeout".
- Support sends the evidence, such as a data availability report or the regulator's responses.
- If something in TSC Enviro™ was set up wrongly, such as an alert limit, support corrects it.
- Your industry writes and sends the reply to the board, using this evidence.
Related articles
- Data Availability Report – how much of the expected data was received.
- Data Gaps After a Network or Power Outage – what happens to data when a gateway goes offline.
- Station Offline or Data Not Updating – find out whether the gateway, the analyser or the network is the cause.
- Reporting a Shutdown or Maintenance Period – record planned shutdowns, maintenance and calibration in TSC Enviro and with the regulator.