Viewing Facility Data Flow

Viewing Facility Data Flow

The Data Flow page shows, for the whole facility, where every gateway's data goes. It helps you check that every parameter reaches the platform and, where required, the regulator.

Open Data Flow

Select Internet of Things (IIoT) > Data Flow in the side menu of TSC Connect. Click Here
The banner at the top shows how many parameters, across how many gateways, are shared with at least one data consumer.

Facility data flow diagram

Gateways are shown on the left, with their number of instruments and parameters, and data consumers on the right, with the number of parameters each receives. Click a gateway to highlight where its data goes. Green lines show data going to the platform (InstaMsg) and orange lines show data going to a regulator.

Every parameter, facility-wide

The table lists every parameter with its Gateway, Field Instrument and Unit, and a column for each data consumer. A tick shows the parameter is shared with that consumer.
  1. Use Search by Parameter Name to find a parameter.
  2. Use the Gateway filter to show one gateway.
If a parameter that must be reported to the regulator has no tick in the regulator column, enable the regulator as a data consumer for its gateway.

Related articles

  1. Managing Data Consumers for a Gateway – choose where a gateway's data is shared.
  2. Configuring a Gateway – polling settings, parsing configuration and pushing config.
  3. Sending Gateway Data to CPCB-ODAMS and State Board Portals – what is needed to report gateway data to regulators.