Data from CloudConnect gateways can be sent to the Central Pollution Control Board (CPCB) OCEMS portal (ODAMS), and to State Pollution Control Board portals, as well as to The Sustainability Cloud. This article explains what is needed and how the connection is set up.

Under CPCB's revised directions, industries with online continuous emission and effluent monitoring must connect to the new OCEMS portal (ODAMS). The gateway timestamps each reading and sends it to the portal over a secure connection.
Before you start
- Check your gateway.
- CPCB requires one gateway for each monitoring station. One gateway cannot serve two stacks or stations.
- The gateway must run a firmware version that supports ODAMS. In TSC Connect, if the gateway shows "Gateway version is not supported" for the CPCB ODAMS data consumer, it needs an upgrade. See Firmware Upgrades for CloudConnect V5 Gateways.
- Older gateways from before the V5 series must be replaced.
- Check your subscription.
- Regulator connectivity (CPCB-ODAMS activation) is ordered separately from your The Sustainability Cloud subscription. Renewing the subscription alone does not turn on regulator reporting. Contact your account manager if you are not sure what you have ordered.
- Get your station approved by CPCB.
- CPCB issues the credentials for your station, such as a token and public key, after it approves the station. Data upload starts only after these are received.
Documents and details support needs
Send these to support when you request a regulator connection:
- The CPCB ODAMS registration sheet for the station.
- A self-declaration on company letterhead, signed and stamped.
- A photo of the monitoring station with its geo-coordinates.
- A photo of the installed gateway.
- The latest calibration report of each analyzer.
- Your Consent to Operate (CTO).
- The portal identifiers issued for your industry and station, such as the industry ID, station ID and device ID, and the token or key details.
- Your The Sustainability Cloud organization and facility, the station names and the MAC address of each gateway.

Send portal tokens, keys and passwords only through the support ticket, never in a group email.
How the connection is set up
- Support checks the gateway, its firmware and your order.
- Support maps each station and parameter to the regulator portal and enables the regulator data consumer for the gateway in TSC Connect. See Managing Data Consumers for a Gateway.
- Data is sent to CPCB at the interval set by CPCB, for example every 15 minutes, and more often during calibration.
- Support confirms when all parameters are updating on the regulator portal. The go-live date depends on CPCB's approval.
Data shows in TSC but not on the regulator portal
- Check that regulator connectivity was ordered and is active.
- Check that the station is approved and the credentials have been shared with support.
- In TSC Connect, check that the regulator data consumer is enabled for the gateway. See Viewing Facility Data Flow.
- If the gateway was replaced, the new gateway must be mapped to the station again. See Replacing a CloudConnect Gateway.
Related articles
- Firmware Upgrades for CloudConnect V5 Gateways – when an upgrade is needed, including for CPCB-ODAMS.
- Replacing a CloudConnect Gateway – move instruments and regulator mapping to a new gateway.
- Data Gaps After a Network or Power Outage – what happens to data when a gateway goes offline.
- Choosing a CloudConnect V5 Gateway Model – compare the V500, V501 and V505 models and their variants.
- Managing Data Consumers for a Gateway – send gateway data to the platform and to regulators.
- Viewing Facility Data Flow – see where each gateway's data goes.
- Connecting Your Industry to CPCB ODAMS (New OCEMS Portal) – register on ODAMS and get your station sending data to CPCB.
- Data Not Showing on CPCB ODAMS – data is live in TSC Enviro but missing on CPCB ODAMS.
- Moving from the Old CPCB OCEMS Portal (RTDMS) to ODAMS – what changes when you move from the old CPCB portal to ODAMS.