Missing Data and Historical Data Downloads

Missing Data and Historical Data Downloads

There are two different needs here: downloading data you already have, and recovering data that is missing.

Download historical data yourself

  1. Select Reports > Parameter in the side menu of TSC Enviro™. Click Here
  2. Choose a Custom Range for the period, then the stations and parameters.
  3. Click Export as to download it, or Request via Email for long periods. The email can take up to an hour.
See Parameter Report. To see every reading exactly as it was received, use the Raw Data Report: See Raw Data Report.
Downloads need an active subscription. If your subscription has expired, renew it first. See Viewing Your Subscription Details.

Can missing data be recovered?

What happenedRecoverable?
The network was down but the gateway had powerPossibly. The gateway keeps reading the instruments and can store readings to send when the connection returns. How much it can store depends on the gateway model and firmware. See Data Gaps After a Network or Power Outage.
The old CPCB portal (RTDMS) or an SPCB portal was down or rejected the dataPossibly. Whether readings can be added to a regulator portal later depends on that portal's rules. Support checks for your station.
CPCB ODAMS (new OCEMS portal) was down or rejected the dataPossibly, once the cause is fixed (for example a device approval or parameter mismatch on ODAMS). It depends on CPCB's rules. Support checks for your station.
The analyser or gateway had no power, or the analyser sent nothingNo. There is no reading to recover.
LogicLadder sends readings as they were received. Values are never created or edited.
To reduce future gaps, power the gateway from a UPS, ask support about a backup connection, and set up offline alerts. See Data Gaps After a Network or Power Outage, Setting Up Offline Alerts.

What to send to support

  1. Industry and station name.
  2. The exact missing time slots.
  3. Which portal is affected: TSC Enviro™, CPCB ODAMS, the old CPCB portal (RTDMS) or which SPCB.
  4. A screenshot showing the gap.
If the checks above don't solve it, raise a ticket with support.

What happens next

Support checks whether the readings exist. If they do, LogicLadder sends them to TSC Enviro™, and to the regulator where its rules allow, and tells you when it is done. Resending to a regulator can take from days to weeks, depending on the portal.